Universal coolant preheaters compatible with all water-cooled engine types, across a wide range of engine-driven applications. Available in power ratings from 1 to 26 kW and multiple voltage configurations to meet diverse installation and operational requirements.
Zerostart, FlowStart and TopStart are Phillips & Temro brands we supply and support. Above 10 kW the range is our own: POWERHEAT 12 – 26 kW, built in France for gensets, ships and rail projects.
Drag the marker to your engine's coolant volume. The matching series are highlighted. Final sizing depends on ambient temperature and target coolant temperature.
Coolant volume
60L
TopStart
1 – 9 kW
Single match for this volume
10 L30 L50 L150 L500 L
POWERHEAT12 – 26 kW
150 – 500 L
TopStart1 – 9 kW
50 – 150 L
FlowStart0,5 – 2 kW
20 – 50 L
Zerostart0,75 – 2,25 kW
10 – 30 L
Easy integration
Fits the system you already have
Simple bypass installation
No modifications to the internal engine cooling system
Compact designs for tight installation envelopes
Suitable for both new build and retrofit installations
Every engine is different. Send us the engine make, model and coolant volume and our engineers confirm the right unit.
Fitted into the coolant circuit, not into the engine
Every heater is delivered with a connection and fixation kit.
Bypass across the engine cooling circuit
01
Tap into the coolant circuit
The heater is installed as a bypass across the engine block. The internal cooling system stays untouched, so warranty and engine approvals are unaffected.
02
Mount and connect
Fixation bracket and hose adapters are supplied. Thermosiphon models rely on natural circulation; forced-flow models carry an integrated pump.
03
Set the temperature and leave it
Fixed thermostats switch between roughly 27 and 50 °C; TopStart is adjustable from 0 to 80 °C and POWERHEAT from 20 to 90 °C, each with a safety thermostat (110 °C and 120 °C STD).
POWERHEAT is built in France, TopStart in Belgium. Every unit is CE marked and supplied from the Netherlands.
0,5 kW ──────── 26 kW
Zerostart
FlowStart
TopStart
POWERHEAT
4series, one supplier
Coverage
0,5 to 26 kW in one range
Thermosiphon, small forced flow, forced flow and high-capacity units from a single supplier, so one enquiry covers the whole fleet.
Contact Us
"90 L coolant, 400 V. Which unit?"
TopStart 4 – 9 kW, 400 V
answered by our engineers
Support
Technical answers in English
Sizing, voltage and installation questions answered by the people who build the systems.
Heating solutions for industrial & marine engines